Technical specifications | Tobii Dynavox PCEye Plus |
---|---|
Medical Device | 93/42/EEC (MDD) - Medical Device Directive, as amended by 2007/47/EC |
Data Streams | Eye tracking (gaze point, eye position, etc.) IR image stream at 30 Hz |
Power Consumption | <2.2 W typical average |
Processing Unit | IS-4L Tobii EyeChip™ with fully embedded processing |
Interface | USB 2.01 or higher |
Track Box2 Dimensions at 65 cm (26’’) Distance |
>40 × 30 cm ellipse |
Operating Distance | 50 - 95 cm 20″ - 37″ |
Screen Size3 | Recommended up to 27" |
Detected Gaze Interaction >30 Hz | 99% for 95% of population4 |
User Calibration (Former Tracking Robustness) |
>99% |
Accuracy | <0.3° ideal5 <1.0° for 65% of population <1.3° for 80% of population <1.7° for 90% of population <1.9° for 95% of population |
Precision | <0.1° ideal5 <0.2° for 65% of population <0.25° for 80% of population <0.3° for 90% of population <0.4° for 95% of population |
Max Head Movement Speed (Eye Position) | 40 cm/s (16 in/s) |
Max Head Tilt | >20° |
Max Yaw, Pitch | 25° |
Visibility | Low visibility (850 nm) |
Flicker | No flicker (30 Hz constant) |
Gaze Latency / Gaze Recovery | 25 ms / 100 ms |
Size (w × h × d) | 322 × 22 × 18 mm 12.7″ × 0.87″ × 0.71″ |
Weight | 280 g 9.9 oz |
System Requirements (Recommended Minimum) | Processor: Dual-Core 2.0 GHz Memory: 4 GB RAM Hard Disk: 450 MB available USB Interface: USB 2.0 or higher |
Compatible Operating Systems | 64-bit Windows 7, 8.1 or 10 |
Compatible Tobii Dynavox Software | Windows Control, Gaze Point, Gaze Viewer, Virtual Remote, Communicator 5, Snap Core First, Compass |
Incompatible Tobii Dynavox Software | Classic Tobii Gaze Interaction Software, Snap Scene, ALL, Boardmaker Student Center |
Microphone | Microphone array consisting of 4 microphones |
Ports | 1 × 3.5 mm Switch connector interface |
1 USB 2.0 BC1.2 provides Tobii IS4 with sufficient power and signal bandwidth.
2 Track box describes the space in front of the eye tracker where the user must have at least one eye to get gaze data. The eye tracker is at a 20° angle looking upward from below the screen.
3 For larger than recommended screens, the limiting parameter is the quality of the gaze accuracy at the upper corners of the screen when the user sits close to the screen.
4 The degree-of-accuracy and precision over percentage-of-population numbers result from extensive testing across representatives of the whole population. We have made use of hundreds of thousands of diagnostic images and performed tests on approximately 800 individuals with different conditions, vision, ethnicities, everyday dust, smudges or blemishes around their eyes, with eyes out of focus, etc. This has resulted in a much more robust and high performance eye tracking experience and a much more realistic representation of true performance across the whole population, not just in a mathematically "ideal" scenario.
5 The "ideal" degree numbers are the previous standard of measuring accuracy and precision, both previously from Tobii and presently from all eye tracking competitors. Though "ideal" numbers are useful to get a general feel about comparative quality and performance, they are not applicable to real world usage in the same way as quantitative degree-of-accuracy and precision over percentage-of-population numbers based on extensive testing across representatives of the whole population.
Download PCEye Plus product leaflet
Technical specifications | Tobii Dynavox EyeR |
---|---|
Medical Device | 93/42/EEC (MDD) - Medical Device Directive, as amended by 2007/47/EC |
Weight |
48 g |
Size (l × h × d) | 284 mm × 9.3 mm × 23.4 mm 11.2” × 0.37” × 0.92” |
Active range of IR transmission | >4 m |
Compatible Operating Systems |
64-bit Windows 7, 8.1 or 10 |
Included Software |
Virtual Remote |
Connectivity | USB 2.0 or higher |
Download EyeR Safety & Compliance